• 400 mm EUROPERL PERLITE, well insulated construction U-value = 0.10
  • Europerl Perlite 70 kg / m³, λ D class 42 mW / m ° C.
    (DS 418, 7th edition, 2011)
  • Rafters
  • Eco Steam Brake B2
  • Formwork
  • Class 2 clothing, e.g. 15 mm list ceiling
  • Grid ceiling rafters on non-utilisable attic insulated with EUROPERL PERLITE
  • This construction provides a reasonable insulation.
    The rafters feet must have a dimension of 45 x 125 mm with a c-c distance max 900 mm
  • The formwork must be a minimum of 22 x 95 mm with a c-c distance max. 400 mm and fixed with two blank nails 34 x 100 mm in rafters feet.
  • The design can be expected to be approved by the Danish Institute of Fire Technology.
  • 255 mm EUROPERL PERLITE, minimal construction U-value = 0.15
  • Requirements in BR 95 & BR-S 98 U = 0.15
  • Requirements for summer cottages U = 0.25
  • Europerl Perlite 70 kg / m &, λ D class 42 mW / m ° C.
    (DS 418.6 edition, Apr. 2002)
  • Rafter
  • Eco Steam Brake B2
  • FormworkClass 2 clothing, such as 15 mm list ceiling
  • Grid rafters ceiling there abuts the non-utilizable attic space insulated with EUROPERL PERLITE
  • Rafter feet must have a dimension of min. 45 x 125 mm with c-c distance max 900 mm.
  • Constructions can be expected to be approved by the Danish Fire Technology Institute in connection with small houses.
  • The ceiling lists should be supported by a formwork of min. 22 x 95 mm with c-c spacing max 400 mm and fixed with two blank nails 34 x 100 in the rafters feet.